Geberit urinal flush control with electronic flush actuation, mains operation, Type 10 cover plate, round
My list (0)
Click on the icon with the 3 dots to have more options for each item.
Technical data
Protection degree IP45 |
Nominal voltage 110–240 V AC |
Operating voltage 4.5 V DC |
Mains frequency 50–60 Hz |
Flow pressure 1–8 bar |
Test pressure, water max. 16 bar |
Test pressure, air / inert gas max. 3 bar |
Flow rate at 1 bar without flow limiter 0.3 l/s |
Flow rate at 1 bar with flow limiter 0.18 l/s |
Interval flush time, factory setting 5 s |
Detection time, factory setting 7 s |
Flush time, adjustment range 1–15 s |
Flush time, factory setting 7 s |
Application purposes
Click on an application purpose to search more products
Characteristics
Click on a characteristic to search more products
Cover plate with securing barWater-saving hybrid mode can be setAdjustable interval flushPreflush can be setPower failure control unitValve-closing function when power failsFunctions can be set and queried with the Geberit Service Handy
Device settings and operation with mobile device via integrated Bluetooth® interfaceCompatible with Geberit Control AppWired networkable with Geberit gateway via GEBUS converterWirelessly connectable with Geberit Gateway via Bluetooth®Compatible with Geberit ConnectFlush volume can be reduced to 0.5 l per flush with regulating screw of installation setTap group II in accordance with DIN 4109
Scope of delivery
Type 10 cover plate with IR window
Infrared control, premounted on mounting frame
Solenoid valve
Power supply unit
Fastening material
Documents
Films
Spare parts
Urinal flush controls with electronic flush actuation, battery / mains operation
Urinal flush controls with electronic flush actuation, battery / mains operation
2009 -
# | Art. no. | Description | Replacement for | Remarks |
---|---|---|---|---|
1 | 241.934.00.1 | Geberit throttle, brass | ||
1.1 | 241.933.00.1 | Geberit regulating screw | ||
2 | 241.931.00.1 | Geberit set of distance bolts (4 pc.) | ||