| Degree of protection IP45 | 
| Nominal voltage 110–240 V AC | 
| Operating voltage 4.5 V DC | 
| Mains frequency 50–60 Hz | 
| Power consumption in standby mode max. 0.1 W | 
| Flow pressure 1–8 bar | 
| Water test pressure max. 16 bar | 
| Flush volume small, adjustment range 0.5 l | 
| Durchfluss bei 100 kPa / 1 bar mit Durchflussbegrenzer 0.18 l/s | 
| Interval flush time, factory setting 5 s | 
| Detection time, factory setting 7 s | 
| Flush time, adjustment range 1–15 s | 
| Flush time, factory setting 7 s | 
| Product material Vitreous china | 
Urinal flush control with power supply unit and solenoid valve
Fastening material
Urinal trap with suction function
Drain strainer
Drain assembly
Inlet set
Water pressure reducing valve

| # | Art. no. | Description | Remarks | 
|---|---|---|---|
| 1 | 243.332.00.1 | Geberit spray head, complete | |
| 1.1 | 243.334.00.1 | Geberit non-return valve for spray head | |
| 1.2 | 243.333.00.1 | Geberit spray head nozzle | |
51 Articles